N-1000 Range
Northern Computers N-1000 panels support either 2 or 4 readers, four relay outputs (DPDT) expandable to twenty outputs, and monitors 16 supervised or unsupervised alarm points. The standard memory on the panel will hold 5,000 card numbers and buffer up to 10,200 transactions. To add more readers or alarm points, simply connect additional panels.

Select the type of N-1000 Panel
you require or scroll down the page
N-1000 Controller   pdf
PassPoint Plus Datasheet   (1,236Kb)
PTQRM - 4 O/P Relay Module  (339Kb)
A and E Specifications  (103Kb) 
The very best security equipment
at very competitive prices 
 
 
 
Northern Part No.    Description  Trade Price 
N-1000-III    N-1000-III    2 Reader advanced door controller and enclosure.
The N-1000-III is a two reader / keypad access control panel. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 5000 code capacity, 10.200 buffer capacity, 4 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes 12 volt battery back-up, detachable terminal blocks, locking enclosure with tamper switch. 12 volt 500mA output for external readers. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:355mm x 456mm x 100mm (W x H x D) 
 
N-1000-III-CB    N-1000-III-CB    2 Reader advanced door controller, printed circuit board only.
The N-1000-III is a two reader / keypad access control printed circuit board. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 5000 code capacity, 10.200 buffer capacity, 4 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes detachable terminal blocks. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:279mm x 279mm x 38mm (W x H x D) 
 
N-1000-III-X    N-1000-III-X    2 Reader advanced expanded door controller and enclosure.
The N-1000-III-X is a two reader / keypad access control panel. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 25,000 code capacity, 6,600 buffer capacity, 8 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes 12 volt battery back-up, detachable terminal blocks, locking enclosure with tamper switch. 12 volt 500mA output for external readers. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:355mm x 456mm x 100mm (W x H x D) 
 
N-1000-III-X-CB    N-1000-III-X-CB    2 Reader advanced door controller, printed circuit board only.
The N-1000-III-X-CB is a two reader / keypad access control printed circuit board. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 25,000 code capacity, 6,600 buffer capacity, 8 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes detachable terminal blocks. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:279mm x 279mm x 38mm 
 
N-1000-IV    N-1000-IV    4 Reader advanced door controller and enclosure.
The N-1000-IV is a four reader, 2 matrix keypad access control panel. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 5000 code capacity, 10.200 buffer capacity, 4 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes 12 volt battery back-up, detachable terminal blocks, locking enclosure with tamper switch. 12 volt 500mA output for external readers. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:355mm x 456mm x 100mm (W x H x D) 
 
N-1000-IV-CB    N-1000-IV-CB    4 Reader advanced door controller, printed circuit board only.
The N-1000-IV is a four reader 2 matrix keypad access control printed circuit board. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 5000 code capacity, 10,200 buffer capacity, 4 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes detachable terminal blocks. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:279mm x 279mm x 38mm 
 
N-1000-IV-X    N-1000-IV-X    4 Reader advanced door controller and enclosure.
The N-1000-III is a two reader / keypad access control panel. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 25,000 code capacity, 6,600 buffer capacity, 8 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes 12 volt battery back-up, detachable terminal blocks, locking enclosure with tamper switch. 12 volt 500mA output for external readers. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:355mm x 456mm x 100mm (W x H x D) 
 
N-1000-IV-X-CB    N-1000-IV-X-CB    4 Reader advanced door controller printed circuit board only.
The N-1000-III is a two reader 2 matrix keypad access control printed circuit board. Supports Wiegand, magnetic stripe, proximity, barcode, vehicle ID, barrium ferrite and biometric devices. 25,000 code capacity, 6,600 buffer capacity, 8 relays (DPDT), 16 supervised alarm inputs, 20mA or RS485 communications (RS485 requires the use of N-485-HUB-2 or N-485-PCI-2 interface). Includes detachable terminal blocks. Requires 16.5vac or 12vdc linear power supply and suppressor kit (S-4) per used (active) relay. Current draw is 1.8Amps maximum. Dimensions:279mm x 279mm x 38mm 
 